this post was submitted on 09 Aug 2026
527 points (98.0% liked)

Technology

87469 readers
3335 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 3 years ago
MODERATORS
 

I've been hearing about these for a few years now. Huge if they work out at a large scale.

you are viewing a single comment's thread
view the rest of the comments
[–] LastYearsIrritant@sopuli.xyz 3 points 2 weeks ago (2 children)

Kind of, yes. But more importantly, it also means it can only push enough power to run at 3c. And that's probably not for the full charge of the battery.

So a 100 amp hour battery rated at 3c can push out 300 amps. Which also means that if the grid needs a short spike in power, it might be limited.

It shouldn't be too hard to get a 15c LiPo battery, which could push 5x as much energy at peak demand.

You'd probably kill the battery if you charged it from 0-100 at 15c, but for short bursts of charging and discharging, it should handle it just fine.

[–] korazail@lemmy.myserv.one 1 points 1 week ago (1 children)

Honestly curious: I'm not a battery or even energy person, but this is interesting.

The charge/discharge efficiencies and rates could just mean we build networks of mixed types? "Trickle" charge/discharge via a slower battery that handles more cycles and is probably way cheaper to build (that's the premise of Na+, right?), but have those batteries back up a more expensive high-rate bank for when power is needed in a burst? Probably a switching problem at that point, which I imagine we already deal with having solar/hydro/fossil/etc.

A Na+ bank sized to handle regular use and charge a Lithium bank when underused so that one is ready for spikes seems like a way to go.

[–] LastYearsIrritant@sopuli.xyz 2 points 1 week ago

That is an option. For smaller setup, capacitors are used for high peak demand applications.

Sometimes a mixed setup is just not worth it, cause the peak demand is the important part, so you end up with like 80% LiPo and 20% Na.

But I'm certainly no expert on the economics of infrastructure battery installations.

[–] ryannathans@aussie.zone 1 points 2 weeks ago

The comment I am replying to is discussing charge rate of 3C, not discharge rate